AG Publications Aquafax Equipment Catalogue
BATTERY SWITCHES
www.aquafax.co.uk
BLUE SEA M-SERIES BATTERY SWITCHES
E-SERIES BATTERY SWITCHES
350 Ampere continuous rating for inboard gasoline and diesel engines. • Tin-plated copper studs for maximum conductivity and corrosion resistance. • Studs accept 3/8" (M10) ring terminals. • 7/8" (22mm) stud length accepts multiple cable terminals. • One-piece terminal stud design never loosens over time. • Case design allows surface or rear panel mounting options. • Label with international legends. • Tactile indicator conveys knob position by feel. • Alternator Field Disconnect (AFD) protects the diodes in the alternator in the event of the switch being switched to the OFF position. Regulatory • CE marked, ISO 8846 • UL Listed - UL 1107 electric power switches • Meets ABYC requirements • Meets UL1500 & SAE J1171 external ignition protection requirements • IP66 protects against powerful water jets
8-28993 8-29004
8-28991/2 8-29002
8-25510 8-25511
Specification:
Cranking Rating: 30 sec. Intermittent Rating: 5 min
1,200A 600A
1,200A 600A
700A* 525A* 350A*
Continuous Rating:
350A
350A
Voltage Maximum Operating:
48V DC
32V DC
32V DC
Terminal Stud Size: Terminal Stud Torque:
3/8"-16 (M10)
3/8"-16 (M10)
3/8"-16 (M10)
140 in-lbs (15.82N•m) max Accept 1/4" (M6) Screw
Mounting Holes:
Cable Size to Meet Ratings**: Cable Clearance for 4/0 cables:
4/0 AWG (95mm 2 )
1.10” (28.0mm)
* Per circuit ** Reducing cable size will reduce current rating.
SWITCH POSITION
BATTERY INPUTS
BATTERY COMBINE
546
DESCRIPTION
PART NO.
8-28993 8-29004 8-28991 8-29002 8-28992 8-25510
Single circuit ON/OFF
2
1
-
Single circuit with AFD
2
1
-
Selector 4 Position †
4
2
Yes
Selector 4 Position with AFD †
4
2
Yes
Selector 3 Position with AFD †
3
2
-
Dual circuit™
2
2
-
Dual circuit plus™ Selector 4 Position with AFD †
8-25511
3
2
Yes
† Make-before-break contact design allows switching between battery banks without power interruption.
8-28991 & 8-29002
8-28993 & 8-29004
ADD-A-BATTERY KITS
DUAL CIRCUIT PLUS™ BATTERY SWITCH • Isolates engine and house circuits using one dual switch. • Switch combines battery banks for emergency starting. AUTOMATIC CHARGING RELAY • Automatically combines battery banks during charging. • Isolates battery banks when discharging and when starting engines. BATTERYLINK ® CHARGER • Integrated ACR provides charging from engine alternator or AC shore power to two battery banks. • 3 Stage: A mains charger with battery temperature compensation. • Includes LED indicator and dual circuit plus battery switch. • Handles 12V alternator up to 65A and 240V AC 50/60Hz.
These include a Dual Circuit Plus™ Battery Switch and an Automatic Charging Relay simplifying switching & automatic charging, so that you just turn the battery switch ON when you board and OFF when you leave. Adding a second battery prevents getting stranded with a dead battery by isolating the start battery from the house loads that can quickly discharge a battery. The Auto Charge Relay combines battery banks when charging and isolates when discharging. The dual circuit battery switch allows both banks to be combined to assist engine starting if required.
8-28992
8-25510
PART NO. BATTERY SWITCH
ACR
ALTERNATORS
8-27649 8-27650 8-27653
m-Series 8-26011 e-Series 8-25511 m-Series 8-26011
m-ACR 8-27601 SI-ACR 8-27610
up to 65A up to 120A up to 65A
Battery Link
8-25511