AG Publications Aquafax Equipment Catalogue

REMOTE BATTERY SWITCHES & RELAYS

www.aquafax.co.uk

MAIN HEADING

500 Ampere Bi-Stable Magnetic Latching Solenoid allows high-amp switching under load where manual control is not required. • 500 Ampere continuous rating. • Bi-Stable Magnetic Latch (ML) – draws no current in the ON or OFF state. • LED output to remotely indicate switch state (requires optional LED). • 3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance. • 7/8" (22mm) stud length accepts multiple cable terminals. • Label recesses for circuit identification. • Silver alloy contacts provide high reliability for switching live loads. • Retail packaging includes remote control contura switch 8-22145. ML SERIES SOLENOID SWITCH

Specification: Voltage Maximum Operating:

32 Volts DC

Switching Cycles:

100,000 Cycles

Amp Operating Current:

100mA when changing state (control circuit - momentary) 300A @ 12V DC - 10,000 cycles 10.1 to 16.5V (12V models), 20.2 to 32.9V (24V models)

Live Current Switching: Control Circuit Voltage:

Terminal Stud Size: Terminal Stud Torque: Ring Terminal Size:

3/8"-16 (M10)

140 in-lb (15.5 N·m)

3/8" (M10)

Terminal Ring Diameter Clearance:

1.18" (30.0mm)

WEIGHT KG (LB)

12V DC PART NO.

24V DC PART NO.

8-27701

8-27703

0.77 (1.69)

8-27701

RATING TABLE DIMENSIONS & RATINGS

Wire Size

Cranking Cranking Intermittent

Continuous

10sec. 2,000A 2,200A 2,500A

1min. 750A 750A 1,100A

5 min. 400A 400A

(UL 1107)

2/0 (70mm 2 ) 4/0 (120mm 2 )

225A 300A 500A

2 x 4/0 (120mm 2 )

700A

Wire Colour

Circuit Function +VDC, 24 Hour

8-22145

Red

553

Black Yellow Brown Orange

Ground

-V DC LED Output

+VDC, To Close +VDC, To Open

Regulatory • CE marked • Meet ISO 8846 ignition protection, and SAE J1171 external ignition protection requirements • IP66 protects against powerful water jets

L-SERIES SOLENOID SWITCH WITH COIL ECONOMIZER

450 Ampere compact solenoid offers remote switching for applications with limited space and no requirement for manual control. • Hermetically sealed contacts. • Activated by an ON–OFF switch mounted remotely. • Integrated coil control minimizes heating and amperage draw. • Mount in a dry location.

Typical Installation

Main Power Contacts: Voltage Max. Operating:

60 Volts DC

Switching Cycles: Terminal Stud Size:

1,000,000 Cycles

5/16" (M8) SPST-NO

Contact Form:

Coil Circuit Input Voltage:

9 to 36V DC

Amp Operating Current:

- Inrush max, 130ms: 3.80 Amps - Holding: 0.13A (12V) , 0.07A (24V)

RATING TABLE

Wire Size

Cranking Cranking Intermittent Continuous 10sec. 1min. 5 min. (UL 1107)

1/0 (50mm 2 ) 2/0 (70mm 2 )

1,000A 1,200A 1,500A

500A 550A 850A

275A 400A 600A

250A 300A 450A

Regulatory: • CE marked, UL Recognized – UL 508 industrial control equipment. • Meets SAE J1171 external ignition protection requirements.

2 x 2/0 (70mm 2 )

PART NO.

VOLTAGE

WEIGHT KG (LB)

8-29012

12/24

0.45 (1.00)

Made with FlippingBook Ebook Creator