AG Publications Aquafax Equipment Catalogue
VOLTAGE SENSING RELAYS
www.aquafax.co.uk
BLUE SEA AUTOMATIC CHARGING RELAYS
M-LVD LOW VOLTAGE DISCONNECT
Optional Features • Remote LED indicates status - requires optional LED or Remote Control Contura Switch with Integrated LED (included in retail package). • External alarm output to provide a low voltage warning prior to disconnect - requires alarm.
Senses low battery voltage and disconnects non-critical loads to save
power for engine starting. • 65 Amp continuous rating • 12V DC voltage input • Faster disconnect at lower battery voltages. • A single press at the remote control switch will delay disconnect. • Load can be manually disconnected using remote control switch. • LED flashing frequency increases as m-LVD approaches disconnect. • Case design allows surface, rear, or front panel mounting options. • Snap-on cover insulates terminal connections. Automatically combines batteries during charging, isolates batteries when discharging and when starting engines. • 65 Amp continuous rating. • 12V/24V DC auto ranging voltage input. • Senses charging on two battery banks. • Case design allows surface, rear, or front panel mounting options. • Snap-on cover insulates terminal connections. • 7/16" (11 mm) stud length • Integrated LED indicates ACR states. • 1/4" × .032" male quick connect terminals for ground and start isolation connections. M-ACR AUTOMATIC CHARGING RELAY WITH OPTIONAL START ISOLATION 8-27635 PART NO. • Integrated LED or optional remote LED indicates status. • 1/4" × .032" male quick connect terminals for ground & control connections.
Specifications: Intermittent Rating: 5 min.:
115A
Continuous Rating:
65A
Nominal Voltage:
12V DC
Cable Size to meet current ratings:
6 AWG (16mm²)
Maximum Cable Size:
1/0 AWG (50mm²)
VOLTAGE
Terminal Stud Size:
1/4"-20 (M6)
12/24
Terminal Stud Length:
7/16" (11mm)
Regulatory: • CE marked, ISO 8846
• Meets UL SAE J1171 external ignition protection requirements • IP67 - protected against immersion up to 1 meter for 30 minutes.
Specifications: Intermittent Rating: Continuous Rating:
5 min. 115A
65A
556
(Combine) Amperage Operating Current: (Open) Amperage Operating Current:
90mA 15mA
Nominal Voltage:
12V / 24V DC
Cable Size to meet current ratings:
6 AWG (16mm²) 1/0 AWG (50mm²)
Maximum Cable Size: Terminal Stud Size: Terminal Stud Length:
1/4 "-20 (M6) 7/16 " (11 mm)
Optional Features • Start Isolation allows temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics from sags and spikes.
Relay Contact Position:
12V DC 13.6V DC 13.0V DC 12.35V DC 12.75V DC 16.0V DC 9.5V DC 10.0V DC
24V DC 27.2V DC 26.0V DC 24.7V DC 25.5V DC
Combine:
(30 sec.) (2 min.) (10 sec.) (30 sec.)
Open:
PART NO.
VOLTAGE
Over Voltage Lockout: Under Voltage Lockout: Under Voltage Recovery:
--
8-27601
12/24
19.0V DC 20.0V DC
Regulatory: • CE marked, ISO 8846 • Meets SAE J1171 external ignition protection requirements. • IP67 - protected against immersion up to 1 meter for 30 minutes.