AG Publications Aquafax Equipment Catalogue

CIRCUIT PROTECTION

www.aquafax.co.uk

BLUE SEA CIRCUIT

Provides medium duty circuit protection for 25 to 150 Amp loads when switching and circuit protection are both required 285 - SERIES CIRCUIT BREAKERS (REPLACES 185-SERIES CIRCUIT BREAKERS)

Provides heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required. 187 SERIES CIRCUIT BREAKERS

• Trip-free - cannot be held closed after trip. • Visible reset lever shows open condition. • Drop-in replacement for 185-Series Circuit Breakers. Regulatory • CE marked • Meets SAE J1171 external ignition protection requirements, †AIC ratings achieved using SAE J1625. • IP67 – protected against immersion up to 1 meter for 30 minutes.

• Single lever operation - clearly visible • Trip-free - cannot be held closed after trip • Self-trimming case eliminates need for mounting panels or trim bezels • Round case for easy installation with standard sized hole saw (panel mount) • Large clearance around terminal studs accepts up to 1/0 AWG lugs • Recessed mounting holes for clean appearance • Robust 5/16"-18 terminals provide high torque connections Regulatory • CE marked • Meets SAE J1171 external ignition. protection requirements. • I P66 - protected against powerful water jets.

AMPS

8-27080 8-27081 8-27082 8-27083 8-27084 8-27085 8-27086 8-27087 8-27088 8-27089 PANEL MOUNT

SURFACE

AMPS

PANEL MOUNT

SURFACE

DC

MOUNT

DC

MOUNT

8-27180 8-27181 8-27182 8-27183 8-27184 8-27185 8-27186 8-27187 8-27188 8-27189

25 30 40 50 60 70 80

8-27135 8-27136 8-27138 8-27139 8-27140 8-27142 8-27143 8-27144 8-27146 8-27148 8-27149 8-27141

25

8-27036 8-27038 8-27039 8-27040 8-27042 8-27043 8-27044 8-27046 8-27048 8-27049 8-27041

30

40

50

60

70

558

100 120 150

80

90

100

120

Specifications: Interrupting Capacity: Voltage Max. Operating: Temp Min. Operating: Temp Max. Operating:

150

3,000A @ 48V DC

200

48V DC

-40°C

85°C

Type: Class:

Thermally Responsive Bi-Metal Blade

Type III – Switchable/Manual Reset – Trip Free

Specifications Interrupting Capacity:

Terminal Stud:

M6 (accepts 1/4" ring terminal)

5,000 Amps @ 12V DC 3,000 Amps @ 24V DC 1,500 Amps @ 42V DC

Terminal Stud Torque:

50 in-lb

Mounting:

1/4" Screw

Panel Mount

Voltage Max. Operating: Temp. Min. Operating: Temp. Max. Operating:

48 Volts DC

-40°C

85°C

Type: Class:

Thermally responsive bi-metal blade Type III - Switchable/Manual reset - trip free

Terminal stud:

5/16"-18

Terminal stud torque:

75 in lb max.

Mounting:

1/4" Screw

Panel Mount

Surface Mount

Surface Mount

Made with FlippingBook Ebook Creator