AG Publications Aquafax Equipment Catalogue
CIRCUIT PROTECTION
www.aquafax.co.uk
BLUE SEA CIRCUIT
Provides medium duty circuit protection for 25 to 150 Amp loads when switching and circuit protection are both required 285 - SERIES CIRCUIT BREAKERS (REPLACES 185-SERIES CIRCUIT BREAKERS)
Provides heavy duty circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required. 187 SERIES CIRCUIT BREAKERS
• Trip-free - cannot be held closed after trip. • Visible reset lever shows open condition. • Drop-in replacement for 185-Series Circuit Breakers. Regulatory • CE marked • Meets SAE J1171 external ignition protection requirements, †AIC ratings achieved using SAE J1625. • IP67 – protected against immersion up to 1 meter for 30 minutes.
• Single lever operation - clearly visible • Trip-free - cannot be held closed after trip • Self-trimming case eliminates need for mounting panels or trim bezels • Round case for easy installation with standard sized hole saw (panel mount) • Large clearance around terminal studs accepts up to 1/0 AWG lugs • Recessed mounting holes for clean appearance • Robust 5/16"-18 terminals provide high torque connections Regulatory • CE marked • Meets SAE J1171 external ignition. protection requirements. • I P66 - protected against powerful water jets.
AMPS
8-27080 8-27081 8-27082 8-27083 8-27084 8-27085 8-27086 8-27087 8-27088 8-27089 PANEL MOUNT
SURFACE
AMPS
PANEL MOUNT
SURFACE
DC
MOUNT
DC
MOUNT
8-27180 8-27181 8-27182 8-27183 8-27184 8-27185 8-27186 8-27187 8-27188 8-27189
25 30 40 50 60 70 80
–
8-27135 8-27136 8-27138 8-27139 8-27140 8-27142 8-27143 8-27144 8-27146 8-27148 8-27149 8-27141
25
8-27036 8-27038 8-27039 8-27040 8-27042 8-27043 8-27044 8-27046 8-27048 8-27049 8-27041
30
40
50
60
70
558
100 120 150
80
90
100
120
Specifications: Interrupting Capacity: Voltage Max. Operating: Temp Min. Operating: Temp Max. Operating:
150
3,000A @ 48V DC
200
48V DC
-40°C
85°C
Type: Class:
Thermally Responsive Bi-Metal Blade
Type III – Switchable/Manual Reset – Trip Free
Specifications Interrupting Capacity:
Terminal Stud:
M6 (accepts 1/4" ring terminal)
5,000 Amps @ 12V DC 3,000 Amps @ 24V DC 1,500 Amps @ 42V DC
Terminal Stud Torque:
50 in-lb
Mounting:
1/4" Screw
Panel Mount
Voltage Max. Operating: Temp. Min. Operating: Temp. Max. Operating:
48 Volts DC
-40°C
85°C
Type: Class:
Thermally responsive bi-metal blade Type III - Switchable/Manual reset - trip free
Terminal stud:
5/16"-18
Terminal stud torque:
75 in lb max.
Mounting:
1/4" Screw
Panel Mount
Surface Mount
Surface Mount
Made with FlippingBook Ebook Creator