AG Publications Aquafax Equipment Catalogue
CIRCUIT PROTECTION
www.aquafax.co.uk
BEP CIRCUIT BREAKER MOULDERS
CIRCUIT BREAKER MODULE Provides 3 CBs ideal for medium duty loads, like waste treatment systems and electric toilets. Designed to separate these loadings from the main DC panel, avoiding voltage spikes. Supplied standard with 1 x 50A and 2 x 25A B Series CBs in a Contour Lock housing for easy modulation. Extra CBs available. Labels ordered separately: SET-714. Part No. 8-93100
CONTOUR CIRCUIT BREAKER HD Allows switchable protection for heavy-duty circuits like Windlasses or Davit winches using Busman Heavy-duty thermal circuit breakers (120). Modular sizing with Contour Lock housing allows easy grouping. LED to indicate circuit is on. Five standard ratings
24HR SERVICE CIRCUIT BREAKER MODULE (4W)
Consists of one 5A and three 15A push to reset Carling CLB Series thermal CBs. Suitable for essential circuits such as bilge pump, auto float switch supplies and stereo memory circuits. The push to reset function ensures essential 24hr circuits cannot be switched off inadvertently. This is contained in the contour lock double module. . Part No. 8-93110
available (see table below). Part No. 8-93102 to 8-93105
MODEL
RATING (A)
L X W X H (MM)
L X W X H (IN)
STUD SIZE
PART NO.
8-93100
707
1 X 50A, 2 X 25A
138 X 69 X 75
5.4 X 2.71 X 3
3/16" 5mm
8-93102
705 - 80A
80
138 X 69 X 75
5.4 X 2.71 X 3
1/4" 6mm
8-93103
705 - 100A
100
138 X 69 X 75
5.4 X 2.71 X 3
1/4" 6mm
8-93104
705 - 135A
135
138 X 69 X 75
5.4 X 2.71 X 3
1/4" 6mm
8-93105
705 - 150A
150
138 X 69 X 75
5.4 X 2.71 X 3
1/4" 6mm
8-93110
706 - 4w
1 x 5A, 3 x 15A
138 X 69 X 75
5.4 X 2.71 X 3
5/32" 4mm
3. Select circuit type and intersect to find wire size . 3% voltage drop: Panel main feeders, bilge blowers, electronics, navigation lights. 10% voltage drop: General lighting, windlasses, bait pumps, general appliances.
CABLE SELECTION CHART
2. Find circuit length in feet (the roundtrip distance from power source to product and back).
1. Locate the current in Amps
571
3% VOLTAGE DROP CIRCUIT TYPE
CURRENT FLOW IN AMPS
10% VOLTAGE DROP
Non-Critical Circuit
Critical Circuit
5A 10A 15A 20A 25A 30A 40A 50A 60A 70A 80A 90A 100A 120A 150A 200A
12 AWG 10
14 AWG 12 AWG
14 AWG 12 AWG 10 AWG 8 AWG
16 AWG 14 AWG
0' – 20'
0' – 6'
8 AWG 6
4 AWG
4 AWG 2
6 AWG
6 AWG 4
AWG
10 AWG 8 AWG
1 AWG 2/0 AWG
16 AWG
30' 50' 65' 80'
10' 15' 20' 25' 30' 40' 50'
AWG
AWG
AWG
12 AWG 10
8 AWG 6
4 AWG
4 AWG
2 AWG
2 AWG
AWG
AWG
14 AWG
1 AWG 0 AWG 2/0 AWG 3/0 AWG
0 AWG 2/0 AWG
2 AWG
6 AWG
4 AWG
2 AWG
3/0 AWG
0 AWG 1 AWG 2/0 AWG 3/0 AWG
0 AWG 1 AWG 2/0 AWG 3/0 AWG 4/0 AWG
10 AWG
6 AWG
12 AWG
8 AWG 6
2 AWG 1
4 AWG
3/0 AWG 4/0 AWG
1 AWG 0 AWG
100' 130' 165' 200'
AWG 0 AWG 2/0 AWG
AWG
2 AWG
4 AWG
2/0 AWG 0 AWG 1 AWG
8 AWG
4 AWG
2 AWG
4/0 AWG
10 AWG
6 AWG 4
0 AWG 1 AWG
3/0 AWG
2 AWG
4/0 AWG
AWG
1 AWG
60' 70' 80' 90' 100' 110' 120' 130'
3/0 AWG
6 AWG
4/0 AWG
2 AWG
2/0 AWG
4 AWG
0 AWG
1 AWG
3/0 AWG
4/0 AWG
8 AWG
METRIC CONVERSION AWG mm 2 AWG mm 2 18 1.0 4 25 16 1.5 2 35 14 2.5 1/0 50 12 4.0 2/0 70 10 6.0 3/0 95 8 10.0 4/0 120 6 16.0
2 AWG
4/0 AWG
CIRCUIT LENGTH
3/0 AWG 4/0 AWG
2/0 AWG
1 AWG
0 AWG
4 AWG 2
AWG
6 AWG
0 AWG 2/0 AWG
4/0 AWG
1 AWG
3/0 AWG
2 AWG
© Copyright 2010 Blue Sea Systems Inc. All rights reserved. Unauthorized copying or reproduction is a violation of applicable laws.
Made with FlippingBook Ebook Creator