AG Publications Aquafax Equipment Catalogue

MASTERVOLT

www.aquafax.co.uk

MAIN HEADING CHARGEMASTER BATTERY CHARGERS

CHARGEMASTER BATTERY CHARGERS - 24V

The ChargeMaster is suitable for recreational and semi-professional use. Easy to install, it includes a detailed display. The ChargeMaster safely charges multiple battery banks at the same time (except model 24/6). 3-step+ charging memory ensures more power and a longer life for your batteries.

Part No.

M43020600

M44020120

Model

24/6

24/12-3

GENERAL SPECIFICATIONS Nominal Output Voltage

24V

24V

Total Charge Current

6A at 28.5V

12A at 26.5V

No. of Battery Outlets

1

3

Charge Current Second Output

N/A

12A

Charge Current Third Output

N/A

12A

Recommended Battery Capacity

25 - 70Ah

24 - 120Ah

Nominal Input Voltage

230V (180-265V) -50/60Hz

120/230V (90-265V) - 50/60Hz

Supplies Your System Without Battery

No

Yes

Display/Read out

1 LED

LED Display

632

Dimensions (H x W x D)

180 x 121 x 50mm

234 x 132 x 60mm

Weight

1kg

1.8kg

Approvals

CE, ABYC, A-31

CE, ABYC, A-31, SAE J1171/ISO 8846 ignition protected

TECHNICAL SPECIFICATIONS Charge Characteristic* Charge Voltage Bulk (25°C)**

IUoUo, automatic / 3-step+ for gel/AGM/wet/Lithium Ion

28.5V (6 hours)

28.8V (8 hours)

Charge Voltage Absorption (25°C)**

28.5V (6 hours)

28.5V (4 hours)

Charge Voltage Float - wet (25°C)**

26.5V

26.5V

Charge Voltage Float - Gel/AGM (25°C)**

27.6V

27.6V

Temperature Compensation

No

-60mV/°C

Voltage Compensation

Automatic

Automatic

DC Consumption

<1mA

<2mA

Full Load Consumption (230V AC)

210W

435W

Current Control Function

No

No

Cos Phi

> 0.95

> 0.98

Temperature Range (ambient temp)

-25°C to 60°C, derating > 40°C

-25°C to 60°C, derating > 25°C

Cooling

Natural Cooling

Vario Fan

Sound Level

< 30 dBA at 1m

< 52 dBA at 1m

Protection Degree

IP65

IP23

Protections

Over temperature, over load, short circuit, high battery, low battery

Masterbus Compatible

N/A

Yes

* The charge characteristic can be set to your requirements. ** The battery charge current can sometimes be specified at 20°C, so take temperature compensation into account.

CONTROL PANELS / ACCESSORIES See pages 569 for further information on Operating, Monitoring & Control Panels and pages 605 for MasterBus system

OPTIONS FOR MASTERBUS MODELS MasterView Read-out (M77010050)

N/A

Option

Remote panel for reading the charge status of your battery charger, including error notifications. Easy View 5 (M77010310) N/A Touch screen panel for reading charge status, current fold-back and/or reducing grid power consumption.

Option

Made with FlippingBook Ebook Creator