MAIN HEADING AC TMRANI SHFERADSYINSGTEMS MASTERVOLT TRANSFER SYSTEMS: REGULATES 230V POWER SOURCES
The Mastervolt transfer system helps you regulate your grid, generator or inverter power and automatically selects the right power sources at the right time. With Mastervolt you can cook and do laundry at the same time or watch TV with the air con on full blast. In addition, Mastervolt transfer systems are suitable for every installation.
THE MASTERVOLT TRANSFER SYSTEM CONTROLS THE FOLLOWING: • Activating and selecting 230V sources: Grid power, inverter and generator with the system switch (adjustable to amperage of shore power, for instance 6A). • Prevents damaging contact between the inverter and other 230V sources. • Fully compatible with Mastervolt systems, and suitable for installations from other brands, other generators and/or inverters.
647
Part No.
M55006010
M55006015
M55003500
Model
Masterswitch 5kw
Masterswitch 10kw
Masterswitch 25kw
INPUT SPECIFICATIONS Nominal Input Voltage Input Voltage Range
230V (50/60Hz) 200-250V AC
230V (50/60Hz) 200-250V AC
230V (50/0=60Hz)
200-250V AC
No. of Inputs No. of Outputs
2
2
2
1
1
1
Dimensions (H x W x D) (mm)
200 x 110 x 115
200 x 110 x 115
291 x 241 x 168
Weight
1.2kg
1.3kg
3.8kg
VERSION Connection for Remote Control Masterbus Compatible LED Indication on Cabinet Nominal Input Current Generator Nominal Input Current Shore Nominal Input Current Inverter
No No No
No No No
No No No
20A 20A N/A N/A
40A 40A N/A N/A
125A 125A
N/A N/A
Earth Leakage Switch Generator Input Switch Time Delay Generator input
No
No
No
0-10 sec (adjustable)
0-10 sec (adjustable)
0-10 sec (adjustable)
OUTPUT SPECIFICATIONS Nominal Current Short break Output Nominal Current Power output Nominal Current Generator Output TECHNICAL SPECIFICATIONS Power Consumption (AC all inputs) Power Consumption (only inverter power) Temperature Range (specified) Temperature Range (allowed) Temperature Range (storage/non operating) Automatic Circuit Breakers
N/A 20A N/A
N/A 40A N/A
N/A
125A
N/A
No, system dependant
No, system dependant
No, system dependant
7 VA
7 VA
26 VA
No, no-load consumption
No, no load consumption
No, no-load consumption
-5°C-60°
-5°C-60°
-5°C-60°C
-25°-70°C (may not meet the specified tolerances)
-60°-80°C
-60°C-80°C
-60°C-80°C
Relative Humidity
Maximum 95%, non condensing Switch on 12-22ms / switch off 4-19ms
Transfer Time
Frequency Watch
No
No
No
MECHANICAL SPECIFICATIONS Cable Size
0.5-10mm 2 / AWG 20-7
0.5-10mm 2 / AWG 20-7
4-50mm 2 / AWG 10-1/10
Protection Degree
IP55
IP55
IP55