example

WARNING LIGHTS A warning lamp can be used on its own or with a buzzer to warn of a potential problem.

ILLUMINATED WARNING LAMPS Supplied without a bulb and should be ordered separately. • 12V bulb - 709931 • 24V bulb - 709932 • 17.2mm hole diameter

These illuminated warning lamps have a chromed bezel and a raised lens. Supplied without a bulb and should be ordered separately. • 12V bulb - 709901 • 24V bulb - 709902 • 19mm diameter hole ILLUMINATED WARNING LAMPS

ELECTRICAL

709038

Part no. 709034 709035 709036 709037 709038 709039

Lamp colour Application

Red Red Red Red

Water temperature

Part no. 709001 709002 709003 709004

Warning lamp colour

Battery

709001

Oil

Red

(!) Warning Heater start Water level

Amber

Amber

Blue

709037

Red

Green

ILLUMINATED WARNING LAMPS Small illuminated warning lamp supplied complete with a 12V bulb. Fits into a 13mm diameter hole.

MULTIFUNCTIONAL WARNING LAMP PANELS Consists of four warning lamps in one housing and supplied complete with bulbs. Warning lamps include: Temperature, Oil, Charge and Heater / Cold Start. • 12V bulb - 709941 • 24V bulb - 709942

Part no. 709021 709022 709023 709024

Warning lamp colour

Red

709023

709062

Part no. 709062 709064

Volt

Amber

Blue

12 24

Green

SWITCHES FOR LOW PRESSURE AND HIGH TEMPERATURE

TEMPERATURE SWITCHES

PRESSURE SWITCHES

• Change for reset 0.5 bar nom • Tolerance: +/- 0.14 bar • Max overload 12 bar • Electrical switching – single pole double throw switch • Rating 5 amp 24V DC resistive, 2 amp inductive • Connections – 3 x 6.35 spades (normally only 2 are used)

• Change for reset 9˚C nom • Tolerance: 20-109˚C +/- 2˚C 110-140˚C +/- 3˚C • Max. overload 25˚C above set point • Electrical switching – single pole double throw switch • Rating 5 amp 24V DC resistive, 2 amp inductive • Connections – 3 x 6.35 spades (normally only 2 are used) TED-DCA-AB-099

TED-DCA-BF-048

Part no.

Thread size

Pressure set at PSI

TED-DCA-BF-048 TED-DCA-BF-069 TED-DCA-BF-104 TED-DCA-BG-083 TED-DCA-BG-124

1/8” BSP Male 1/8” BSP Male 1/8” BSP Male 1/8” NPT Female 1/8” NPT Female

7

Part no.

Thread size

Temperature set at

10 15 12

TED-DCA-AA-095 TED-DCA-AB-095 TED-DCA-AB-096 TED-DCA-AB-098 TED-DCA-AB-099 TED-DCA-AE-099 TED-DCA-AC-090 TED-DCA-AJ-095 TED-DCA-AN-095 TED-DCA-AN-097 TED-DCA-AN-099

1/2” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” NPTF Male 1/4” BSP Male

95˚C 95˚C 96˚C 98˚C 99˚C 99˚C 90˚C 95˚C 95˚C 97˚C 99˚C

18 For 1/8” NPT thread adaptor bushes, see page 189.

ACCESSORIES

710490 Will activate a small warning lamp or buzzer. Threaded 1/8” NPT male set at approximately 7 PSI. 710918 Pressure switch junction adaptor Machined adaptor piece, 1/8” BSP taper male screws onto the engine block. The two female 1/8” BSP ports can be used for a gauge sender and / or a pressure switch.

M14 x 1.5

5/8” x 18 UNF 5/8” x 18 UNF 5/8” x 18 UNF

710490

710918

TED-DCA-53

Please see Gauges section for senders, pages 183-184.

TED-DCA-53 Provides splash protection for DCA terminals. Suitable for both pressure and temperature Teddington switches.

63

info@asap-supplies.com

www.asap-supplies.com

01502 716993

Made with FlippingBook - Online Brochure Maker