example
WARNING LIGHTS A warning lamp can be used on its own or with a buzzer to warn of a potential problem.
ILLUMINATED WARNING LAMPS Supplied without a bulb and should be ordered separately. • 12V bulb - 709931 • 24V bulb - 709932 • 17.2mm hole diameter
These illuminated warning lamps have a chromed bezel and a raised lens. Supplied without a bulb and should be ordered separately. • 12V bulb - 709901 • 24V bulb - 709902 • 19mm diameter hole ILLUMINATED WARNING LAMPS
ELECTRICAL
709038
Part no. 709034 709035 709036 709037 709038 709039
Lamp colour Application
Red Red Red Red
Water temperature
Part no. 709001 709002 709003 709004
Warning lamp colour
Battery
709001
Oil
Red
(!) Warning Heater start Water level
Amber
Amber
Blue
709037
Red
Green
ILLUMINATED WARNING LAMPS Small illuminated warning lamp supplied complete with a 12V bulb. Fits into a 13mm diameter hole.
MULTIFUNCTIONAL WARNING LAMP PANELS Consists of four warning lamps in one housing and supplied complete with bulbs. Warning lamps include: Temperature, Oil, Charge and Heater / Cold Start. • 12V bulb - 709941 • 24V bulb - 709942
Part no. 709021 709022 709023 709024
Warning lamp colour
Red
709023
709062
Part no. 709062 709064
Volt
Amber
Blue
12 24
Green
SWITCHES FOR LOW PRESSURE AND HIGH TEMPERATURE
TEMPERATURE SWITCHES
PRESSURE SWITCHES
• Change for reset 0.5 bar nom • Tolerance: +/- 0.14 bar • Max overload 12 bar • Electrical switching – single pole double throw switch • Rating 5 amp 24V DC resistive, 2 amp inductive • Connections – 3 x 6.35 spades (normally only 2 are used)
• Change for reset 9˚C nom • Tolerance: 20-109˚C +/- 2˚C 110-140˚C +/- 3˚C • Max. overload 25˚C above set point • Electrical switching – single pole double throw switch • Rating 5 amp 24V DC resistive, 2 amp inductive • Connections – 3 x 6.35 spades (normally only 2 are used) TED-DCA-AB-099
TED-DCA-BF-048
Part no.
Thread size
Pressure set at PSI
TED-DCA-BF-048 TED-DCA-BF-069 TED-DCA-BF-104 TED-DCA-BG-083 TED-DCA-BG-124
1/8” BSP Male 1/8” BSP Male 1/8” BSP Male 1/8” NPT Female 1/8” NPT Female
7
Part no.
Thread size
Temperature set at
10 15 12
TED-DCA-AA-095 TED-DCA-AB-095 TED-DCA-AB-096 TED-DCA-AB-098 TED-DCA-AB-099 TED-DCA-AE-099 TED-DCA-AC-090 TED-DCA-AJ-095 TED-DCA-AN-095 TED-DCA-AN-097 TED-DCA-AN-099
1/2” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” BSP Male 3/8” NPTF Male 1/4” BSP Male
95˚C 95˚C 96˚C 98˚C 99˚C 99˚C 90˚C 95˚C 95˚C 97˚C 99˚C
18 For 1/8” NPT thread adaptor bushes, see page 189.
ACCESSORIES
710490 Will activate a small warning lamp or buzzer. Threaded 1/8” NPT male set at approximately 7 PSI. 710918 Pressure switch junction adaptor Machined adaptor piece, 1/8” BSP taper male screws onto the engine block. The two female 1/8” BSP ports can be used for a gauge sender and / or a pressure switch.
M14 x 1.5
5/8” x 18 UNF 5/8” x 18 UNF 5/8” x 18 UNF
710490
710918
TED-DCA-53
Please see Gauges section for senders, pages 183-184.
TED-DCA-53 Provides splash protection for DCA terminals. Suitable for both pressure and temperature Teddington switches.
63
info@asap-supplies.com
www.asap-supplies.com
01502 716993